医药学论文:纸片法与培养发酵法检测大肠菌群结果对比分析
关键词:纸片法;大肠菌群;灵敏度;特异度
摘要:目的 探讨改进纸片法检测大肠菌群的判断标准。 方法 对纸片法检测大肠菌群的纸片反应结果状况进行详细记录后,将纸片以无菌操作转入单料乳糖胆盐发酵管中,用发酵法来证实其大肠菌群的阴阳性结果,再作统计分析。 结果 按GB14934-94判断纸片法大肠菌群的阴阳性,其灵敏度为73.3%,特异度为99.2%;若按作者提出的标准进行判断,其灵敏度为97.9%,特异度为90.3%。二者比较灵敏度有显著性差异(P< 0.05)。消毒剂的残留可能是导致纸片法结果判断出偏差的主要原因。 结论 据本实验结果分析,建议改进和完善纸片法大肠菌群的判断标准,以更准确地反映大肠菌群检出的真实情况。
关键词:纸片法;大肠菌群;灵敏度;特异度
Comparison of results of slip method with culture ferment method in detection of E.coli.
Abstract:Objective To compare the slip method with culture ferment method in the detection of E.coli and for improving the accuracy of judgment of detection results. Methods Slip method was used for monitoring the contamination status of cooking uten-sils and the slips were put into lactose bile salts broth tubes for confirmation of the detection results by using ferment method.The re-sults were statistically analyzed. Results Based on the judgment standard of GB14934-94,the sensitivity and specificity of the slip method were73.3%and99.2%respectively.But the sensitivity and specificity were,based on the standard proposed by the author,97.9%and90.3%,respectively.The difference of the sensitivities was significant(P< 0.05),and the main cause of dif-ference in judgment of the results was the residual of the disinfectant. Conclusion Thus it is suggested that the standard for judg-ment of results in detection of E.coli be modified so as to improve the accuracy of detection.
摘要:目的 探讨改进纸片法检测大肠菌群的判断标准。 方法 对纸片法检测大肠菌群的纸片反应结果状况进行详细记录后,将纸片以无菌操作转入单料乳糖胆盐发酵管中,用发酵法来证实其大肠菌群的阴阳性结果,再作统计分析。 结果 按GB14934-94判断纸片法大肠菌群的阴阳性,其灵敏度为73.3%,特异度为99.2%;若按作者提出的标准进行判断,其灵敏度为97.9%,特异度为90.3%。二者比较灵敏度有显著性差异(P< 0.05)。消毒剂的残留可能是导致纸片法结果判断出偏差的主要原因。 结论 据本实验结果分析,建议改进和完善纸片法大肠菌群的判断标准,以更准确地反映大肠菌群检出的真实情况。
关键词:纸片法;大肠菌群;灵敏度;特异度
Comparison of results of slip method with culture ferment method in detection of E.coli.
Abstract:Objective To compare the slip method with culture ferment method in the detection of E.coli and for improving the accuracy of judgment of detection results. Methods Slip method was used for monitoring the contamination status of cooking uten-sils and the slips were put into lactose bile salts broth tubes for confirmation of the detection results by using ferment method.The re-sults were statistically analyzed. Results Based on the judgment standard of GB14934-94,the sensitivity and specificity of the slip method were73.3%and99.2%respectively.But the sensitivity and specificity were,based on the standard proposed by the author,97.9%and90.3%,respectively.The difference of the sensitivities was significant(P< 0.05),and the main cause of dif-ference in judgment of the results was the residual of the disinfectant. Conclusion Thus it is suggested that the standard for judg-ment of results in detection of E.coli be modified so as to improve the accuracy of detection.
编辑推荐:
下载Word文档
温馨提示:因考试政策、内容不断变化与调整,长理培训网站提供的以上信息仅供参考,如有异议,请考生以权威部门公布的内容为准! (责任编辑:长理培训)
-
国家电网30270试题
-
湖南中烟7463试题
-
湖南统招专升本不连网,流畅做题
-
长沙理工大学考研培训4532试题
13年品牌值得信赖
已有 22658 名学员学习以下课程通过考试
网友评论(共0条评论)
精品课程
更多
10781人学习
相关推荐
图书更多+
- 电网书籍
- 财会书籍
- 其它工学书籍
拼团课程更多+
- 电气拼团课程
- 财会拼团课程
- 其它工学拼团
热门排行
-
- 长理培训微信公众号
- 每日推送精彩考试资讯
长按二维码识别
微信搜索“ 长理培训”
-
- 加入QQ群一起来考国网!
- QQ群号:223940140
点击进入
长理培训客户端 资讯,试题,视频一手掌握
去 App Store 免费下载 iOS 客户端
点击加载更多评论>>